User Tools

Site Tools


atmos:3d-paws:und00200

3D-PAWS - UND 00200

Summary

  • Serial Number - UND00200
  • NCAR CHORDS ID - 65
  • UND CHORDS ID -
  • Location - Clifford Hall Roof (South Side Pole Outside of Clifford Hall
  • Status - Inactive

Teamviewer Info

  • ID: 313 583 415
  • Pass Word: Standard Airborne Team Password

Instruments

Anemometer Inactive
Wind Vane Inactive
Radiation Shield Inactive
Light Sensor Inactive
Rain Gauge Inactive

Issue: Upgrade from Jessie to Stretch

Instrument log

  • 12/16/2020: Anemometer is unbalanced
  • 12/18/2020: Reset Power
  • 01/08/2020: Anemometer re balanced. UV lighter sensor had been blown over but has been realigned
  • 03/15/2021: Station power cycled
  • 05/09/2021: Raspberry Pi suffered water damage, Pi was removed from housing box but frame still needs to be removed from roof. Pi needs replacement. Wind Vane will be updated to digital version and program will be updated to latest version before redeployment
  • 02/23/2022: Undergoing repairs, Wind Vane is updated to digital version and currently troubleshooting before final re-assembly and re-deployment.
  • 10/23/2022: Removed from roof. Inconstant and poor data is being recorded. currently inspecting for loose wires and replacing as needed. So far only the radiation shield wiring harness has been replaced with shielded variant. instruments appear functional.
atmos/3d-paws/und00200.txt · Last modified: 2022/10/03 20:04 by david.brannon