atmos:citation:instruments:status
Differences
This shows you the differences between two versions of the page.
atmos:citation:instruments:status [2016/03/12 17:59] – kjhibert | atmos:citation:instruments:status [2020/01/29 17:25] (current) – external edit 127.0.0.1 | ||
---|---|---|---|
Line 17: | Line 17: | ||
|Sidefacing #2 Right |M300 Priminary Monitor | |Sidefacing #2 Right |M300 Priminary Monitor | ||
|Sidefacing #2 Right |M300 Keyboard Tray | |Sidefacing #2 Right |M300 Keyboard Tray | ||
- | |Sidefacing #2 Right |[[http:// | + | |Sidefacing #2 Right |[[http:// |
|Sidefacing #2 Right |Gas Phase Sampler - Space Studies | |Sidefacing #2 Right |Gas Phase Sampler - Space Studies | ||
|Sidefacing #3 Right |DC Power Distribution | |Sidefacing #3 Right |DC Power Distribution | ||
Line 43: | Line 43: | ||
|Right Wing, Outer Down Tube |[[http:// | |Right Wing, Outer Down Tube |[[http:// | ||
|Right Wing, Outside PMS Can |[[http:// | |Right Wing, Outside PMS Can |[[http:// | ||
- | |Left Wing, Inside PMS Can | + | |Left Wing, Inside PMS Can |
Line 99: | Line 99: | ||
|10 |110 |King Slave | N/A |10 volts |1.0 | |10 |110 |King Slave | N/A |10 volts |1.0 | ||
|11 |111 |King Signal | |11 |111 |King Signal | ||
- | |12 |112 |CPC Flow Meter | N/A | 5 volts |0.3895 | + | |12 |112 |CPC Flow Meter | N/A | 5 volts |0.3895 |
- | |13 |113 |CCNC Dtemp | 107 |10 volts |2.3461 | + | |13 |113 |CCNC Dtemp | 107 |10 volts |2.3461 |
|14 |114 |TDL High Bit | N/A |10 volts |1.0 | |14 |114 |TDL High Bit | N/A |10 volts |1.0 | ||
|15 |115 |TDL Low Bit | N/A |10 volts |1.0 | |15 |115 |TDL Low Bit | N/A |10 volts |1.0 | ||
Line 107: | Line 107: | ||
|18 |118 |Inlet Pressure | |18 |118 |Inlet Pressure | ||
|19 |119 |GustBox St. Press. | |19 |119 |GustBox St. Press. | ||
- | |20 |120 |CCNC Top Temp | 107 |10 volts |4.8505 | + | |20 |120 |CCNC Top Temp | 107 |10 volts |4.8505 |
- | |21 |121 |CCNC Laser Power | 107 |10 volts |235.07 | + | |21 |121 |CCNC Laser Power | 107 |10 volts |235.07 |
- | |22 |122 |CCNC Status | + | |22 |122 |CCNC Status |
- | |23 |123 |CCNC Photodetector | + | |23 |123 |CCNC Photodetector |
|24 |124 |Nev_TWC_col_volt | |24 |124 |Nev_TWC_col_volt | ||
|25 |125 |Nev_TWC_col_curr | |25 |125 |Nev_TWC_col_curr | ||
Line 140: | Line 140: | ||
|/dev/ser17 |RS422 | |/dev/ser17 |RS422 | ||
|/dev/ser18 |RS232 | |/dev/ser18 |RS232 | ||
- | |/dev/ser19 |RS232 | + | |/dev/ser19 |RS232 |
|/dev/ser20 |RS232 | |/dev/ser20 |RS232 | ||
|/dev/ser21 |RS232 | |/dev/ser21 |RS232 | ||
Line 159: | Line 159: | ||
|1 | | |1 | | ||
|2 |192.168.0.104|Spec 2D-S Probe (2DS) |100 MB | Installed | |2 |192.168.0.104|Spec 2D-S Probe (2DS) |100 MB | Installed | ||
- | |3 |192.168.0.100|High Volume Particle Sampler (HVPS3) #2 |100 MB | Installed | + | |3 |192.168.0.100|High Volume Particle Sampler (HVPS3) #2 |100 MB | Not Installed |
- | |4 |192.168.0.102|Cloud Particle Imager (CPI) |100 MB | Installed | + | |4 |192.168.0.102|Cloud Particle Imager (CPI) |100 MB | Not Installed |
|5 |192.168.0.103|High Volume Particle Sampler (HVPS3) | |5 |192.168.0.103|High Volume Particle Sampler (HVPS3) | ||
|6 |192.168.0.110|M300 Data System | |6 |192.168.0.110|M300 Data System | ||
|7 |192.168.0.111|CalAmp Data Radio |100 MB | Installed | |7 |192.168.0.111|CalAmp Data Radio |100 MB | Installed | ||
- | |8 |192.168.0.140|CSI | + | |8 |192.168.0.140|CSI |
===== KVM Switch ===== | ===== KVM Switch ===== | ||
Line 171: | Line 171: | ||
|2 |High Volume Particle Sampler (HVPS3) | |2 |High Volume Particle Sampler (HVPS3) | ||
|3 |Spec 2D-S Probe (2DS) | | |3 |Spec 2D-S Probe (2DS) | | ||
- | |4 |Cloud Particle Imager (CPI) | | + | |4 |
|5 |M300 Data System | |5 |M300 Data System | ||
|6 | |6 | ||
|7 | |7 | ||
- | |8 |High Volume Particle Sampler (HVPS3) #2 | | + | |8 |UTC TAS | |
====== Equipment Status ====== | ====== Equipment Status ====== |
atmos/citation/instruments/status.1457805544.txt.gz · Last modified: 2020/01/29 17:25 (external edit)